Dongguan Daying Electronic Technology Co., Ltd.
Technical service
HomeTechnical serviceTroubleshooting

GSM Alarm Series Precautions and Frequently Asked Questions

Time : 2012/12/21 Hits : 10960 Font : Small Medium Larger [back]

1, GSM Burglar Alarm Installation Notes:

1) boot the host after 15 seconds after the hosts into normal operation.
2) If the distance fortified start, alarm remote alarm host must complete all information transmission only after receiving other operations. 3) outside the alarm when the alarm number screech, 1 minute 30 seconds after the alarm stops automatically. 4) regularly check the alarm status of the host to use the SIM card (such as: network signal, recharge time payment, etc.). 5) take the card, and card to turn off the power.
6) periodic testing of the alarm system working state.
7) detection wireless sensor, low battery, please replace the battery.
8) Install all the matching probes, must be professionals (dealers) to guide complete.
9) wired probe wiring, control switch wiring must be done by a professional guide.
10) the host and the distance between the probe should be within 100 meters.


2, GSM burglar alarm using the FAQ:

1) Press the remote control or wireless zone alarm, "Wireless" light is blinking momentarily? A: The action occurs, the host receives the wireless signal, "Wireless" light to blink, or wireless receiving part of the fault. 2) SMS alarm and voice alarm phone numbers phone number at the first set of numbers 1,2,3 in order of priority? A: The alarm occurs, send text messages and automatic dialing of numbers 1, 2 in accordance with the order, with the first number of the first Group 1 received a report of information, we recommend that you set a good first set of numbers. 3) the set of related operations with the remote, why can not immediately carry out the next operation? A: the set of related and remote operation, the host to return a short message to the mobile phone set or other authorized groups of mobile phone, complete the process requires about 20 seconds to wait for one of the most time, the shortest about 6 seconds. 4) understanding of how remote the machine is in normal working condition?
A: Call the phone number of the machine, if they can hear the phone ringing, the unit normal GSM signal, such as would like to learn more about the local state, send relevant SMS command to search. 5) In accordance with the instructions to verify the password without sending the machine instructions, why not deal with this machine? A: Please check whether your phone number in the correct format to be set into the unit group of SMS alarm phone number, if not set in, the phone number to send the machine does not deal with such instructions. 6) SMS alarm and voice alarm phone number phone number must be the same?
A: The unit is not required in that regard. Alarm SMS phone number must be China Mobile, China Unicom’s GSM or CDMA mobile phone number; voice alarm telephone numbers can be mobile or fixed telephone. 7) The wireless detectors and remote from the environmental impact by installing it?
A: by the installation environment. If your room layout of the metal shield of serious or complex, must choose to install the field test sites.

Next: Home security monitoring market demand growth in the rise
Copyright © 2011 Dongguan Daying Electronic Technology Co., Ltd. All Rights Reserved
Address:5th Floor, D #, Futai High-Tech Park, No.8 Qingfeng South Road, Tangxia Town, Dongguan City, Guangdong Province, PRC China. Tel:86-769-82553706 82553753 
Website:http://www.dygsm.cn E-mail:ls@dygsm.com Post:518000